Category: Klixon heater

Klixon heater

Sensata devices are used in automotive, appliance, aircraft, industrial, military, heavy vehicle, heating, air conditioning, data, telecommunications, recreational vehicle and marine applications.

Airpax also offer a full-line of circuit breakers, speed and position sensors, fuses and high voltage power switches. These products are found in a variety of industries, including telecommunications, industrial, recreational vehicles, HVACR, marine, military, medical, information processing, electronic power supply, power generation, over-the-road trucks, construction, agricultural and alternative energy applications.

Product Contacts:

Serving the industrial, military and aerospace markets, BEI Sensors provides an extensive range of products from standard off-the-shelf to completely customized solutions for any challenging application.

The comprehensive product line includes optical and magnetic encoders, Hall-effect sensors, potentiometers, inclinometers, electronic interface modules, wireless modules, and a variety of product accessories. Specialized products for extreme applications include those for wash-down and corrosive environments, extended operating temperatures, high shock and vibration, and products certified for hazardous area use.

At Sensata Technologies, innovation and technology combine to exceed our Customer's most demanding performance requirements. Klixon controls, protectors, circuit breakers and thermostats help prevent damage from overheating and fires in everything from commercial heating and air conditioning systems to refrigerators, cars and lighting.

The Snap-In version of the IEG brings mounting simplification and international spacing together in a package that is aesthetically enhanced.

The IEGS securely snaps into a rectangular cut-out, eliminating the need for panel mounting hardware and the associated costs. The face plate of the IEGS is a clean, black matte and it satisfies the increasing demand for front panel components that are designed with ergonomic considerations.

Designed specifically for 35mm DIN rail, Airpax ICL series Rail-Mount Hydraulic Magnetic circuit breakers offer the advantage of quick and easy mounting or removal which results in efficient and economical wiring while conserving space. They provide the reliable performance associated with hydraulic magnetic circuit protection.

These circuit breakers are designed to mount on standard 35mm DIN rails, such as 35x7. Higher voltage power architectures will be increasingly deployed in data center, telecom and other applications to improve energy efficiency and reduce operating expenses. TheE-Frame circuit breaker combines power switching with accurate, reliable circuit protection in a compact single or multipole unit. The unit is ideal for branch circuit applications such as EDP, air conditioners, panel boards and lighting controls.

The Klixon 5BT series thermostat is a high reliability, hermetically sealed thermal switch. The single pole, double throw design allows versatility and economy in providing two functions within the same device.

Typically these Klixon switches are used to control and indicate at a preset temperature. One pole can control a cooling fan and the other pole can indicate impending danger.

The 5BT thermostat is the ideal choice where quality and reliability in a double throw device are critical. Klixon hermetic miniature and sub—miniature snap—action switches are ideal for extremely harsh and demanding environments as found in aircraft, military, aerospace, and aircraft engines applications.

We offer a wide choice of precision switches ideally suited for rugged applications. Sensata Technologies also manufactures a hermetically sealed snap—acting pressure switch line for applications in aerospace and electronics where high reliability and resistance to severe environments is essential. For over 30 years the Sensata Technologies MA10 has provided reliable protection in a variety of small domestic and personal care appliances.

The MA10 has set the world standard in the field of open type temperature—sensitive safety cut—outs. YS10 was developed to protect people and property from accidents occuring in hair dryers, fan heaters, and other products. Thermal protector for motors, fluorescent ballasts, temperature sensing controls - Up to 18 amps AC on—winding motor protector. The Klixon protector is a field proven miniature protector developed to protect electrical equipment against overheating.

In addition to being small and lightweight, the unit is both temperature and current sensitive. Since the is sealed to withstand varnish dipping, it can be mounted directly in windings where it can best sense the true temperature of the electrical equipment.Standard Opening Temperature Opening Temp.

Lead Wire Configurations State-of-the-art automated lead processing can produce lead wires to meet customer application needs for overall length, terminated connectors and stripped length requirements! Sleeving In order to achieve optimum heat transfer from the protected medium or ambient to the thermostat, the 7AM has been designed with the case connected to the bimetallic disc.

However, this features also makes it necessary to electrically insulate the 7AM from the mounting surface. Typically, this is accomplished with a Mylar sleeve available in 0.

Custom markings and other sleeve materials can also be provided. These ratings are applicable for 10, cycles. All 7AM platform style thermostats and lead wire assemblies are built under the quality assurance system ISO Ultimate Trip Current vs. Current in 25C Ambient Approximate: to be used for selecting samples only 7AM performance is dependent upon the applied current. Use these curves to determine which 7AM will trip in the manner required for your application.

Note: Our stocked parts come complete with 6 inch leads and mylar insulating sleeve. Standard Opening Temperature. Unless specified otherwise by the customer, the following tolerances apply to all assemblies. Klixon is a registered trademark of Texas Instruments, Inc. Current in 25C Ambient Approximate: to be used for selecting samples only. It is a miniature, snap-acting, thermally operated device that is a proven performer in protection technology.

It is the right choice for applications where available space is at a premium. Mod-Tronic can provide these units with a variety of leads, terminations and insulating sleeves to meet specific requirements, including nickel strip leads for NI-CAD battery packs. Part Numbers. Opening Temperature in degrees Celcius.If you have questions, please contact us or call us at SinceAir Engineering has been supporting major manufacturing facilities around the world.

We truly appreciate how important your plant reliability is to you and thank you in advance for working with us. All replacement parts are designed to exact OEM specifications, offering equal to or better performance based on each manufacturer's stringent specifications. Although our prices are updated frequently, manufacturer and supplier pricing are constantly changing.

After purchase, please wait for final confirmation from our team on delivery and final pricing. Recent Posts. All compressed air systems have unique supply and demand characteristics, but one thing they have in …. Should saving energy be of interest to the industrial compressor user? If you are using compres ….

Featuring ultra quiet, depe …. Rating Required Select Rating 1 star worst 2 stars 3 stars average 4 stars 5 stars best. Review Subject Required.

klixon heater

Comments Required. Current Stock:. Warranty Information XY SinceAir Engineering has been supporting major manufacturing SinceAir Engineering has been supporting major manufacturing facilities around Customers Also Viewed.

Klixon Motor Protector Wiring Diagram

SinceAir Engineering has been supporting major manufacturing facilities around the Add to Cart. SinceAir Engineering has been supporting majorDo not use this item for any installation or repair of potable water applications. This product does not comply with the "Safe Drinking Water Act," which requires that products meet low-lead standards in order to be used in systems providing water for human consumption drinking or cooking. This item is for non-potable non-human consumption water applications only.

This product does not comply with the Safe Drinking Water Act, which requires that products used in any system providing water for human consumption drinking or cooking to meet low-lead standards. Please check the box below to confirm you are aware that this item is for non-potable water applications only. This product will NOT be used in the installation or repair of a potable water human consumption application.

When you order this item, we then special order it for you from the manufacturer. Therefore, our standard return policy does not apply to this item. Manufacturer's warranty still applies. I understand that once I order this item I cannot cancel or return it. Failure to comply with this could result in substantial property damage, severe personal injury or death. Please enter the email address associated with your account and we will send you a link to reset your password.

Your password reset link is on its way. If you have problems accessing your account, please contact us at and we'll help you out. If you think this is a mistake, please contact Customer Service at or email us. We try to always offer you the lowest prices possible, but some manufacturers require that we only show these low prices once you take further action. To see the price, simply add the item to your cart or sign in.

At this time, we do not carry this unit. We list it on our site because we do sell replacement parts for this unit. Please contact us with any questions: We are away right now. Our Live Chat hours are:. Feel free to send us a message and we will follow up during our normal business hours:. Email Us. Review Score. Apply Filters.Collection of klixon motor protector wiring diagram.

A wiring diagram is a streamlined standard photographic depiction of an electrical circuit. It shows the components of the circuit as streamlined shapes, and the power as well as signal connections between the tools. A wiring diagram usually provides info concerning the family member setting and also arrangement of tools as well as terminals on the tools, to assist in structure or servicing the gadget.

A pictorial representation would certainly show more detail of the physical appearance, whereas a wiring diagram uses a much more symbolic symbols to stress affiliations over physical look. A wiring diagram is typically made use of to repair troubles and making sure that all the connections have been made as well as that whatever is existing.

Compressor Overload Protector Testing! How it Works!

Click on the image to enlarge, and then save it to your computer by right clicking on the image. A wiring diagram is an easy graph of the physical connections and physical format of an electrical system or circuit.

It shows exactly how the electrical cords are interconnected and could also reveal where fixtures and also elements could be linked to the system. Use wiring layouts to help in building or making the circuit or electronic device. They are also beneficial for making repair services. DIY enthusiasts make use of electrical wiring diagrams but they are also typical in house structure and auto repair.

A home builder will certainly want to confirm the physical place of electric outlets as well as light components making use of a wiring diagram to stay clear of pricey mistakes and constructing code offenses. A schematic shows the strategy and function for an electric circuit, yet is not interested in the physical design of the wires. Electrical wiring representations show just how the wires are linked as well as where they must situated in the actual device, in addition to the physical connections between all the components.

Unlike a photographic diagram, a wiring diagram makes use of abstract or simplified shapes as well as lines to show parts.

Klixon Pressure Switches

Pictorial diagrams are typically images with labels or highly-detailed drawings of the physical components. If a line touching another line has a black dot, it indicates the lines are connected.

Most icons used on a wiring diagram resemble abstract versions of the real items they represent. A switch will be a break in the line with a line at an angle to the wire, much like a light button you could turn on and off.

A resistor will certainly be stood for with a series of squiggles representing the restriction of present flow. An antenna is a straight line with three little lines branching off at its end, similar to a genuine antenna.Finding and restoring, setups and uses in the shop. We have some great FAQ's, click the link above! I'm a newbie here on this forum. I've found a lot of interesting and helpful information here already thanks!

I'm sorry if this question was already answered on the forum but I couldn't find it. In its past life somebody must have had a problem with the Klixon Thermal Breaker and removed it like all the other safety devices on this saw. I have a hole in the end bell where the reset button goes. Anyway, after I discovered what that hole was supposed to have in it I ordered a replacement Klixon protector from Wolfe. The good news is it arrived today yeah!

The bad news is that I expected a two terminal SPST type device that would wire inline with the motor winding. What I have in my hand is a three terminal device!? I did some digging on the web and found the data sheet on the part. It's not very helpful; no example on how it is intended to be wired. Two of the terminals are what you would expect functioning as an inline switch, the extra terminal is at the end of a 'heating wire' that is wired across to one of the switch terminals.

Since I have no example to go by I don't know if this 'heater' is used in this application or simply left floating. So, does anyone know about this thing? Hope this helps The data sheet does indicate the two wide terminals are the main contacts for the breaker switch.

I'm sure wiring it in series with the winding won't cause any problems. I want to check that there isn't something I need to do about that 'heater' terminal to make sure the thing works properly i.

I also attached a wiring diagram for my GWI showing how the Klixon is wired. My Klixon terminals were marked Thank you for the missing puzzle pieces that allowed me to figure this out. For anyone who might be curious, and for the general knowledge base, this is what I discovered:. The data sheet on the part is a. It doesn't have a great theory of operation but it does have a good exploded view that makes it pretty easy to see how it works:.

The Klixon has two current paths. When the temperature of the disk gets hot enough the stresses in metal layers cause the disk to 'snap' open breaking the connection between 1 and the other terminals. This is pretty much how a normal circuit breaker works. I think the klixon is designed to be slower acting than a typical circuit breaker however. You don't want it tripping under transient startup or loading conditions.

klixon heater

Power is sourced on pin 1. This appears to be the main source of heat to trip the contacts open.Remember Me? Page 1 of 2 1 2 Last Jump to page: Results 1 to 13 of Red wire, brown wire, black wire. On a volt system one wire has to be a common connection, one wire has to be the common to the X terminal on the defrost timer, and the other wire has to control the common to the evap fans.

Which wire is which? Close on rise? Close on fall? PHM PHM The conventional view serves to protect us from the painful job of thinking. If wired that way. Is it a Klixon ?

If so, the center terminal should be the common, I would think. If it's a three-wire Klixon Brand style with two leads together on one side and the third lead oppositeohm out the leads at room temperature. The two with continuity will tell you that one is common and the other terminator. The secret to which-is-which is that the fan lead and the terminator are alway opposite each other, so with this you can determine how to connect the t'stat even if all three wires are the same color like with the cheap Mars Klixons I get at the supply house As for the ones with all three leads on the same side, I think man form trane is correct that the center lead is alway common.

So again, at room temperature, the two that have continuity are the common and termination. If the common is in the middle, then the open lead is fan. This is a cobbled Bev-Air It used to have seperate fan and termination switches. But now it has one of those three-wire universal switches. I got there and found no diagram on the unit, and no stat like that in the truck, the evap solid ice, and no common to the defrost heaters.

Somebody 'fixed' it last week and now won't come back. So I get called and see what I think they did.

klixon heater

Which may be today or tomorrow if things go smoothly and I can ever get out of the office! It just occured to me: maybe the wrong switch is wired wrong AND is defective besides! I'll feel better making the wrong thing work right. Is there a reason they can't include a wiring diagram of the switch in the package? I do this when I don't know which is which.

Originally Posted by Dowadudda. Originally Posted by wannafreeze. Blue and black closed warm room temp. Blue and red closed cold. This is what happened and I think happened - Some one came to fix it. It originally had a four-wire setup: one close-on-fall 'klixon' for the evap fans and one close-on-rise 'klixon' for the defrost termination.

They replaced those two with a single three-wire. The problem was that the original defrost switch closed common to the X terminal. Whereas the original fan switch closed power to the fan motors.


Comments